Standard specifications
Reference technical specification
Values refer to the standard range. Each project is re-sized based on the geological report, load zone and car park layout.
- Load-bearing structure
- S275JR steel, hot-dip galvanised to UNI EN ISO 1461, 80 µm
- Types
- Single pitch, symmetrical double pitch, cantilever, butterfly
- Standard spans
- 5.0 / 10.0 / 15.0 m — 5.0 m column spacing
- Clear height
- 2.50 m (cars) — 4.50/5.00 m (heavy vehicles)
- Design loads
- Snow and wind per NTC 2018 — zones I–IV, use class II
- Modules
- Bifacial glass-glass 580–620 Wp, frame integrated into the roof
- Conversion
- Three-phase string inverters 50–125 kW, per-string monitoring
- Stormwater
- Gutters integrated into the beams, downpipes inside the columns
- EV charging
- AC 22 kW and DC 60–150 kW chargers, OCPP 1.6J / 2.0.1
- Foundations
- Precast plinths, micropiles or driven piles per geological report